-
Rates
- Daily$35.00
- Weekly $105.00
- Weekend $52.50
For longer periods,please contact us at rentals@fusioncine.com
Rental Rate Day Charge Schedule
- 1 Day Rental = 1 Day Charge
- 1 to 3 Day Rental = Charge for each day (3 Day Charge)
- 3 to 7 Day Rental = 3 Day Charge
- Weekend (Saturday / Sunday) = 1.5 Day Charge
- Month Rental (28 Days) = 10 Day Charge
Equipment Pick Up and Drop Off Times
Equipment pick up – Equipment will be ready the day before the rental date between 4pm and 6pm (Monday to Friday) or at the time of opening the day of the rental (8am)
Equipment Return – Equipment must be returned between 8am and 10am the day following the rental date (Monday to Friday) or the Monday following a weekend.
If pick up or drop off times are outside of these hours them additional charges may apply.
Insurance- All equipment rentals require a Certificate of Insurance or Deposit before any item can leave Fusion Cine. Get covered using our Fusion Cine Insurance Program
Please note that we rent equipment across Canada, but currently only facilitate rentals out of our Vancouver location, so rentals outside of this area may require additional shipping time.
Extron ADA 4 300 MX & ADA 4 300 MX HV One Input, Four Output Distribution Amplifiers.
General Specifications | Details | ADA 2 300 /300 HV | Unity | ADA 4/6 300 MX/MX HV | 0.7V or 1.0V, switch-selectable | Bandwidth | ADA 2 300 MX/MX HV | 400 MHz (-3dB), fully loaded | ADA 4/6 300 MX/MX HV | 300 MHz (-3dB), fully loaded | Video input | Number/signal type | ADA 2 300, ADA 4/6 300 MX | 1 RGBS, RGsB, RsGsBs, component video, S-video, composite video | ADA 2 300 HV, ADA 4/6 300 MX HV | 1 RGBHV, RGBS, RGsB, RsGsBs, component video, S-video, composite video | Connectors | ADA 2 300, ADA 4/6 300 MX | 4 BNC female | ADA 2 300 HV, ADA 4/6 300 MX HV | 5 BNC female | Minimum/maximum levels | Analog: 0.3V to 1.5V p-p with no DC offset at unity gain | Impedance | 75 ohms | Horizontal frequency | ADA 2 300, ADA 4/6 300 MX | 15 kHz to 135 kHz | ADA 2 300 HV, ADA 4/6 300 MX HV | 15 kHz to 150 kHz | Vertical frequency | ADA 2 300/300 HV | 30 Hz to 150 Hz | ADA 4/6 300 MX/MX HV | 15 Hz to 140 Hz | Return loss | ADA 2 300/300 HV | -42dB @ 5 MHz | ADA 4/6 300 MX/MX HV | -38.5dB @ 5 MHz | AC/DC coupling | Yes, switch-selectable | Video output | Number/signal type | ADA 2 300, ADA 4/6 300 MX | 2/4/6 RGBS, RGsB, RsGsBs, component video, S-video, composite video | ADA 2 300 HV, ADA 4/6 300 MX HV | 2/4/6 RGBHV, RGBS, RGsB, RsGsBs, component video, S-video, composite video | Connectors | ADA 2 300, ADA 4/6 300 MX | 2/4/6 x 4 BNC female (depending on the model) | ADA 2 300 HV, ADA 4/6 300 MX HV | 2/4/6 x 5 BNC female (depending on the model) | Minimum/maximum levels | 0.3V to 1.5V p-p | Impedance | 75 ohms | Return loss | ADA 2 300/300 HV | -80dB @ 5 MHz | ADA 4/6 300 MX/MX HV | -44dB @ 5 MHz | DC offset | ADA 2 300/300 HV | ±5mV maximum, AC coupled | ADA 4/6 300 MX/MX HV | ±13mV maximum with input at 0 offset | Sync | Input type | RGBHV (HV models only), RGBS, RGsB, RsGsBs | Output type | RGBHV (HV models: only), RGBS, RGsB, RsGsBs | Input level | Analog or TTL: 0.5V to 5V p-p | Output level | ADA 2 300/300 HV | 5V p-p (TTL) | ADA 4 300 MX/MX HV | Analog or TTL (selectable): 1.0V, 4.0V p-p | ADA 6 300 MX/MX HV | Analog or TTL: (selectable) 0.5V to 5V p-p | Gain | 1V or 4V p-p, switch-selectable | Input impedance | 510 ohms | Output impedance | 75 ohms | Max input voltage | 5V p-p | Input sensitivity | 0.5V to 5.0V p-p | Max. propagation delay | ADA 2 300/300 HV | 60 nS | ADA 4/6 300 MX/MX HV | 34.8 nS | Max. rise/fall time | ADA 2 300/300 HV | 4 nS | ADA 4/6 300 MX/MX HV | 4.8 nS | Polarity | Positive or negative | General | Power | ADA 2 300/300 HV | 100VAC to 240 VAC, 50/60 Hz, 2 watts, external, auto-switchable; to 9VDC, 1 | A power supply. | All other models | 100VAC to 240VAC, 50/60 Hz, internal, auto-switchable | ADA 4 300 MX/MX HV | 7 watts | ADA 6 300 MX/MX HV | 10 watts | Temperature/humidity | Storage -40° to +158°F (-40° to +70°C) / 10% to 90%, non-condensing | Operating +32° to +122°F (0° to +50°C) / 10% to 90%, non-condensing | Rack mount | ADA 2 300/300 HV | No | All other models | Yes, with optional 2U shelf # 60-030-01, 2U front panel #60-030-10, or | 3U front panel #60-126-01 | Enclosure type | Metal | Enclosure dimensions | ADA 2 300/300 HV | 1.75" H x 4.6" W x 4.7" D | 4.4 cm H x 11.7 cm W x 11.9 cm D | (Depth excludes connectors.) | ADA 4/6 300 MX | 3.4" H x 8.5" W x 6.3" D: (2U high, <half rack width) | 8.6 cm H x 21.6 cm W x 16.0 cm D | (Depth excludes connectors.) | ADA 4/6 300 MX HV | 4.3" H x 8.4" W x 6.3" D: (<3U high, <half rack width) | 10.8 cm H x 21.0 cm W x 16.0 cm D | (Depth excludes connectors.) | Product weight | ADA 2 300 | 1.3 lbs (0.6 kg) | ADA 2 300 HV | 1.4 lbs (0.6 kg) | ADA 4 300 MX | 3.5 lbs (1.6 kg) | ADA 4 300 MX HV | 4.0 lbs (1.8 kg) | ADA 6 300 MX | 3.9 lbs (1.8 kg) | ADA 6 300 MX HV | 4.4 lbs (2.0 kg) | Shipping weight | ADA 2 300, ADA 2 300 HV | 3 lbs (1.4 kg) | ADA 4 300 MX | 5 lbs (2.3 kg) | ADA 4 300 MX HV | 6 lbs (2.7 kg) | ADA 6 300 MX | 6 lbs (2.7 kg) | ADA 6 300 MX HV | 7 lbs (3.2 kg) | Vibration | ISTA/NSTA 1A in carton (International Safe Transit Association) | Listings | UL, CUL | Compliances | CE, FCC Class A, VCCI, AS/NZS, ICES | MTBF | 30,000 hours |
---|